NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 1/Piece
Request Sample
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (15)
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
  • NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
Find Similar Products

Basic Info.

Model NO.
ABC Cable
Current
DC & AC
Insulation Material
XLPE
Sheath Material
None
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC, CE, RoHS
Model
ABC Cable
Brand
Hnbf
Number of Cores
1--4
Color
Customized
Trade Term
Fob/CIF/CFR...
Sample
Providing
Transport Package
Wooden Drum
Specification
0.6/1kv Al/XLPE
Trademark
HNBF Cable
Origin
China
HS Code
8544492100
Production Capacity
500km Per Month

Product Description

1.Production Description:
ABC cable(Aerial Bundled Cables or Aerial Bundled Conductors)are several phase conductors insulated and tightly bundled together with bare/insulated netral conductor for use in overhead power lines. The phase core and neutral core usually are AAC or AAAC with XLPE insulation.

2.Standards:
AERIAL BUNDLED CABLE    NFC 33-209
No. of Conductor and Area Phase Conductor Neutral Messenger Street Lighting Conductor Approximate Overall Diameter Approximate Cable Weight
Number of Wires Nominal Diameter of Bare Conductors Nominal Thickness of Insulating Nominal Insulated Core Diameter Number of Wires Nominal Diameter of Bare Conductors Nominal Thickness of Insulating Nominal Insulated Core Diameter Number of Wires Nominal Diameter of Bare Conductors Nominal Thickness of Insulating Nominal Insulated Core Diameter
mm2 Nos. mm mm mm Nos. mm mm mm Nos. mm mm mm mm kg/km
2x16 7 4.8 1.2 7.2 - - - - - - - - 14.2 126
2x25 7 6.0 1.4 8.8 - - - - - - - - 17.6 194
2x35 7 7.0 1.6 10.2 - - - - - - - - 20.4 266
2x50 7 8.1 1.6 11.3 - - - - - - - - 22.6 341
4x16 7 4.8 1.2 7.2 - - - - - - - - 17.2 252
4x25 7 6.0 1.4 8.8 - - - - - - - - 21.2 388
4x35 7 7.0 1.6 10.2 - - - - - - - - 24.6 533
3x25+54.6 7 6.0 1.4 8.8 7 9.5 1.6 12.7 - - - - 30 514.1
3x25+54.6+1x16 7 6.0 1.4 8.8 7 9.5 1.6 12.7 7 4.8 1.2 7.2 30 580.7
3x25+54.6+2x16 7 6.0 1.4 8.8 7 9.5 1.6 12.7 7 4.8 1.2 7.2 30 647.3
3x25+54.6+3x16 7 6.0 1.4 8.8 7 9.5 1.6 12.7 7 4.8 1.2 7.2 30 713.8
3x35+54.6 7 7.0 1.6 10.2 7 9.5 1.6 12.7 - - - - 33 621.2
3x35+54.6+1x16 7 7.0 1.6 10.2 7 9.5 1.6 12.7 7 4.8 1.2 7.2 33 687.8
3x35+54.6+2x16 7 7.0 1.6 10.2 7 9.5 1.6 12.7 7 4.8 1.2 7.2 33 754.4
3x35+54.6+3x16 7 7.0 1.6 10.2 7 9.5 1.6 12.7 7 4.8 1.2 7.2 33 820.9
3x50+54.6 7 8.1 1.6 11.3 7 9.5 1.6 12.7 - - - - 36 735.0
3x50+54.6+1x16 7 8.1 1.6 11.3 7 9.5 1.6 12.7 7 4.8 1.2 7.2 36 801.6
3x50+54.6+2x16 7 8.1 1.6 11.3 7 9.5 1.6 12.7 7 4.8 1.2 7.2 36 868.2
3x50+54.6+3x16 7 8.1 1.6 11.3 7 9.5 1.6 12.7 7 4.8 1.2 7.2 36 934.8
3x70+54.6 12 9.9 1.8 13.5 7 9.5 1.6 12.7 - - - - 37.5 975.8
3x70+54.6+1x16 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 4.8 1.2 7.2 37.5 1042.3
3x70+54.6+2x16 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 4.8 1.2 7.2 37.5 1108.9
3x70+54.6+3x16 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 4.8 1.2 7.2 37.5 1175.5
3x70+54.6+1x25 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 6.0 1.4 8.8 40 1077.3
3x70+54.6+2x25 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 6.0 1.4 8.8 40 1178.9
3x70+54.6+3x25 12 9.9 1.8 13.5 7 9.5 1.6 12.7 7 6.0 1.4 8.8 40 1280.4
3x70+N70 12 9.9 1.8 13.5 7 10.5 1.5 13.5 - - - - 41 1013.3
3x70+N70+1x16 12 9.9 1.8 13.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 41 1079.9
3x70+N70+2x16 12 9.9 1.8 13.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 41 1146.4
3x70+N70+3x16 12 9.9 1.8 13.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 41 1213.0
3x95+N70 19 11.2 1.8 14.8 7 10.5 1.5 13.5 - - - - 44 1196.2
3x95+N70+1x16 19 11.2 1.8 14.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 44 1262.8
3x95+N70+2x16 19 11.2 1.8 14.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 44 1329.3
3x95+N70+3x16 19 11.2 1.8 14.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 44 1395.9
3x120+N70 19 12.2 1.8 15.8 7 10.5 1.5 13.5 - - - - 46 1350.5
3x120+N70+1x16 19 12.2 1.8 15.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 46 1417.1
3x120+N70+2x16 19 12.2 1.8 15.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 46 1483.7
3x120+N70+3x16 19 12.2 1.8 15.8 7 10.5 1.5 13.5 7 4.8 1.2 7.2 46 1550.2
3x150+N70 19 14.1 1.7 17.5 7 10.5 1.5 13.5 - - - - 48 1660.9
3x150+N70+1x16 19 14.1 1.7 17.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 48 1727.5
3x150+N70+2x16 19 14.1 1.7 17.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 48 1794.0
3x150+N70+3x16 19 14.1 1.7 17.5 7 10.5 1.5 13.5 7 4.8 1.2 7.2 48 1860.6
3x120+N95 19 12.2 1.8 15.8 19 12.5 1.6 15.7 - - - - 47 1413.7
3x120+N95+1x16 19 12.2 1.8 15.8 19 12.5 1.6 15.7 7 4.8 1.2 7.2 47 1480.3
3x120+N95+2x16 19 12.2 1.8 15.8 19 12.5 1.6 15.7 7 4.8 1.2 7.2 47 1546.9
3x120+N95+3x16 19 12.2 1.8 15.8 19 12.5 1.6 15.7 7 4.8 1.2 7.2 47 1613.4
3x150+N95 19 14.1 1.7 17.5 19 12.5 1.6 15.7 - - - - 49 1724.1
3x150+N95+1x16 19 14.1 1.7 17.5 19 12.5 1.6 15.7 7 4.8 1.2 7.2 49 1790.7
3x150+N95+2x16 19 14.1 1.7 17.5 19 12.5 1.6 15.7 7 4.8 1.2 7.2 49 1857.2
3x150+N95+3x16 19 14.1 1.7 17.5 19 12.5 1.6 15.7 7 4.8 1.2 7.2 49 1923.3

3.Characteristics:
*Rated voltage Uo/U is 0.6/1kv.
*Max.Continuouspermissive working temperature of conductor: PVC insulation should be not more than 70ºC,and XPLE insulation should be not more than 90ºC.
*The installation temperature of cable should not less than -20ºC.
*When overall diameter of cable(D) is less than 25mm, permissive bending radius of cable should be not less than 4D. When 
 overall diameter of cable(D) is equal to and above 25mm, permissive bending radius of cable should be not less than 6D.
 
 
ABC Cable
We have the complete and systemly production process in each aspects:

1).100% product inspect from raw material to the finished products;

2).All the products have the test report.


 
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable


 
CERTIFICATIONS
1.ISO9001
2.CCC

NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
 
PACKAGING and SHIPPING
For the ABC cable, we usually use the standard wooden drum to package as the belowing picture. We can design the different package types according to the customers' requirements.
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable

COMPANY INFORMATION
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
Henan Baofeng Cable Co.Ltd. is founded by one of the most professional manufacturers. We specialize in producing and exporting all kinds of wires and cables. We have advanced tech-staff, advanced equipment and 25 years' experience engineer.
 
 
BEST SERVICES
 
NFC Standard 33-209 Aluminum with XLPE Insulated ABC Cable
      Since we were founded, we have been built favorable business relationship with many customers                          from all over the world.

1.Custom Merchandise: We can make cables as your need including the color, size and so on. And we also offer OEM/ODM.

2.Own Factory: Reliable source of raw materials, we can offer you the factory price.

3.Free Sample: Free sample to provide, but the sample freight must be paied by customers own.

4.Speed Delivery: 15-30 days, professional transport team.

5.All type test: Professional technical equipment ensure the high quality.
 

Welcome to visit at any time.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier