IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)

Product Details
Customization: Available
Warranty: 12 Months
Trade Terms: Fob CFR CIF
Still deciding? Get samples of US$ 1/Meter
Request Sample
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (15)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
  • IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
Find Similar Products
  • Overview
  • Product Description
  • Certificates
  • Packing
  • International Fairs
Overview

Basic Info.

Model NO.
control cable
Sample
Provided
Advantages
Competitive Price
Transport Package
Wooden & Steel-Wooden Drums
Specification
aluminium
Trademark
HNBF Cable
Origin
Zhengzhou, China
HS Code
8544601900
Production Capacity
2500km/Month

Product Description

 
Product Description

IEC 60502 Type Cable

0.6/1 kV CVV-S

IEC 60502 (2-15 core)

Application For supervisory electrical equipment,station control circuits,outdoor,suitable installation in dry or wet

cable treches.

Conductor Concentric Stranded copper wire

Insulation PVC Black color

Identification Printed White number on the surface of Black insulation

Filler Suitable filler

Binding tape Suitable tape

Inner sheath PVC Black color

Shield Annealed copper tape

Binding tape Suitable tape

Outher Sheath PVC Black color

2 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
2 0.5 7/0.30 0.8 1.0 1.8 12.5 36.0 0.0162 180 500/D
0.75 7/0.37 0.8 1.0 1.8 13.0 24.5 0.0142 195 500/D
1 7/0.40 0.8 1.0 1.8 13.0 18.1 0.0135 205 500/D
1.5 7/0.50 0.8 1.0 1.8 14.0 12.1 0.0115 230 500/D
2.5 7/0.67 0.8 1.0 1.8 15.0 7.41 0.0093 280 500/D
4 7/0.85 1.0 1.0 1.8 17.0 4.61 0.0092 375 500/D
6 7/1.04 1.0 1.0 1.8 18.5 3.08 0.0078 450 500/D

3 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
3 0.5 7/0.30 0.8 1.0 1.8 13.0 36.0 0.0162 195 500/D
0.75 7/0.37 0.8 1.0 1.8 13.5 24.5 0.0142 215 500/D
1 7/0.40 0.8 1.0 1.8 13.5 18.1 0.0135 225 500/D
1.5 7/0.50 0.8 1.0 1.8 14.5 12.1 0.0115 260 500/D
2.5 7/0.67 0.8 1.0 1.8 15.5 7.41 0.0093 325 500/D
4 7/0.85 1.0 1.0 1.8 18.0 4.61 0.0092 445 500/D
6 7/1.04 1.0 1.0 1.8 19.0 3.08 0.0078 545 500/D

4 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
4 0.5 7/0.30 0.8 1.0 1.8 13.5 36.0 0.0162 220 500/D
0.75 7/0.37 0.8 1.0 1.8 14.0 24.5 0.0142 245 500/D
1 7/0.40 0.8 1.0 1.8 14.5 18.1 0.0135 260 500/D
1.5 7/0.50 0.8 1.0 1.8 15.5 12.1 0.0115 300 500/D
2.5 7/0.67 0.8 1.0 1.8 16.5 7.41 0.0093 385 500/D
4 7/0.85 1.0 1.0 1.8 19.0 4.61 0.0092 530 500/D
6 7/1.04 1.0 1.0 1.8 20.5 3.08 0.0078 660 500/D

5 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
5 0.5 7/0.30 0.8 1.0 1.8 14.5 36.0 0.0162 250 500/D
0.75 7/0.37 0.8 1.0 1.8 15.0 24.5 0.0142 280 500/D
1 7/0.40 0.8 1.0 1.8 15.5 18.1 0.0135 295 500/D
1.5 7/0.50 0.8 1.0 1.8 16.5 12.1 0.0115 345 500/D
2.5 7/0.67 0.8 1.0 1.8 18.0 7.41 0.0093 445 500/D
4 7/0.85 1.0 1.0 1.8 20.5 4.61 0.0092 620 500/D
6 7/1.04 1.0 1.0 1.8 22.5 3.08 0.0078 780 500/D

6 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
6 0.5 7/0.30 0.8 1.0 1.8 15.5 36.0 0.0162 270 500/D
0.75 7/0.37 0.8 1.0 1.8 16.0 24.5 0.0142 305 500/D
1 7/0.40 0.8 1.0 1.8 16.5 18.1 0.0135 320 500/D
1.5 7/0.50 0.8 1.0 1.8 17.5 12.1 0.0115 375 500/D
2.5 7/0.67 0.8 1.0 1.8 19.0 7.41 0.0093 290 500/D
4 7/0.85 1.0 1.0 1.8 22.0 4.61 0.0092 685 500/D
6 7/1.04 1.0 1.0 1.8 24.0 3.08 0.0078 865 500/D

7 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
7 0.5 7/0.30 0.8 1.0 1.8 15.5 36.0 0.0162 275 500/D
0.75 7/0.37 0.8 1.0 1.8 16.0 24.5 0.0142 315 500/D
1 7/0.40 0.8 1.0 1.8 16.5 18.1 0.0135 330 500/D
1.5 7/0.50 0.8 1.0 1.8 17.5 12.1 0.0115 395 500/D
2.5 7/0.67 0.8 1.0 1.8 19.0 7.41 0.0093 520 500/D
4 7/0.85 1.0 1.0 1.8 22.0 4.61 0.0092 730 500/D
6 7/1.04 1.0 1.0 1.8 24.0 3.08 0.0078 930 500/D

8 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
8 0.5 7/0.30 0.8 1.0 1.8 16.0 36.0 0.0162 310 500/D
0.75 7/0.37 0.8 1.0 1.8 17.0 24.5 0.0142 350 500/D
1 7/0.40 0.8 1.0 1.8 17.0 18.1 0.0135 370 500/D
1.5 7/0.50 0.8 1.0 1.8 18.5 12.1 0.0115 445 500/D
2.5 7/0.67 0.8 1.0 1.8 20.0 7.41 0.0093 590 500/D
4 7/0.85 1.0 1.0 1.8 23.5 4.61 0.0092 835 500/D
6 7/1.04 1.0 1.0 1.8 25.5 3.08 0.0078 1070 500/D

9 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
9 0.5 7/0.30 0.8 1.0 1.8 17.0 36.0 0.0162 340 500/D
0.75 7/0.37 0.8 1.0 1.8 18.0 24.5 0.0142 390 500/D
1 7/0.40 0.8 1.0 1.8 18.0 18.1 0.0135 415 500/D
1.5 7/0.50 0.8 1.0 1.8 19.5 12.1 0.0115 495 500/D
2.5 7/0.67 0.8 1.0 1.8 21.5 7.41 0.0093 660 500/D
4 7/0.85 1.0 1.0 1.8 25.0 4.61 0.0092 945 500/D
6 7/1.04 1.0 1.0 1.8 27.5 3.08 0.0078 1215 500/D

10 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
10 0.5 7/0.30 0.8 1.0 1.8 18.0 36.0 0.0162 370 500/D
0.75 7/0.37 0.8 1.0 1.8 19.0 24.5 0.0142 425 500/D
1 7/0.40 0.8 1.0 1.8 19.5 18.1 0.0135 445 500/D
1.5 7/0.50 0.8 1.0 1.8 20.5 12.1 0.0115 540 500/D
2.5 7/0.67 0.8 1.0 1.8 23.0 7.41 0.0093 720 500/D
4 7/0.85 1.0 1.0 1.8 27.0 4.61 0.0092 1030 500/D
6 7/1.04 1.0 1.0 1.8 29.5 3.08 0.0078 1325 500/D

11 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
11 0.5 7/0.30 0.8 1.0 1.8 18.5 36.0 0.0162 395 500/D
0.75 7/0.37 0.8 1.0 1.8 19.5 24.5 0.0142 455 500/D
1 7/0.40 0.8 1.0 1.8 20.0 18.1 0.0135 480 500/D
1.5 7/0.50 0.8 1.0 1.8 21.0 12.1 0.0115 580 500/D
2.5 7/0.67 0.8 1.0 1.8 23.5 7.41 0.0093 780 500/D
4 7/0.85 1.0 1.0 1.8 28.0 4.61 0.0092 1125 500/D
6 7/1.04 1.0 1.0 1.8 30.5 3.08 0.0078 1450 500/D

12 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
12 0.5 7/0.30 0.8 1.0 1.8 18.5 36.0 0.0162 400 500/D
0.75 7/0.37 0.8 1.0 1.8 19.5 24.5 0.0142 460 500/D
1 7/0.40 0.8 1.0 1.8 20.0 18.1 0.0135 490 500/D
1.5 7/0.50 0.8 1.0 1.8 21.0 12.1 0.0115 595 500/D
2.5 7/0.67 0.8 1.0 1.8 23.5 7.41 0.0093 805 500/D
4 7/0.85 1.0 1.0 1.8 28.0 4.61 0.0092 1160 500/D
6 7/1.04 1.0 1.0 1.8 30.5 3.08 0.0078 1500 500/D

13 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
13 0.5 7/0.30 0.8 1.0 1.8 19.0 36.0 0.0162 435 500/D
0.75 7/0.37 0.8 1.0 1.8 20.0 24.5 0.0142 505 500/D
1 7/0.40 0.8 1.0 1.8 20.5 18.1 0.0135 530 500/D
1.5 7/0.50 0.8 1.0 1.8 22.0 12.1 0.0115 645 500/D
2.5 7/0.67 0.8 1.0 1.8 24.5 7.41 0.0093 875 500/D
4 7/0.85 1.0 1.0 1.8 29.0 4.61 0.0092 1275 500/D
6 7/1.04 1.0 1.0 1.9 32.0 3.08 0.0078 1665 500/D

14 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
14 0.5 7/0.30 0.8 1.0 1.8 19.0 36.0 0.0162 435 500/D
0.75 7/0.37 0.8 1.0 1.8 20.0 24.5 0.0142 505 500/D
1 7/0.40 0.8 1.0 1.8 20.5 18.1 0.0135 540 500/D
1.5 7/0.50 0.8 1.0 1.8 22.0 12.1 0.0115 660 500/D
2.5 7/0.67 0.8 1.0 1.8 24.5 7.41 0.0093 900 500/D
4 7/0.85 1.0 1.0 1.8 29.0 4.61 0.0092 1305 500/D
6 7/1.04 1.0 1.0 1.9 32.0 3.08 0.0078 1715 500/D

15 Core CVV-S Control Cable

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.)
mm
Maximum conductor resistance (at 20C)
Ohm/km
Minimum insulation resistance
(at 70C)
Ohm/km
Cable weight
(Approx.)
kg/km
Standard Length
m
15 0.5 7/0.30 0.8 1.0 1.8 20.0 36.0 0.0162 475 500/D
0.75 7/0.37 0.8 1.0 1.8 21.0 24.5 0.0142 550 500/D
1 7/0.40 0.8 1.0 1.8 21.5 18.1 0.0135 585 500/D
1.5 7/0.50 0.8 1.0 1.8 23.0 12.1 0.0115 715 500/D
2.5 7/0.67 0.8 1.0 1.8 25.5 7.41 0.0093 980 500/D
4 7/0.85 1.0 1.0 1.8 30.5 4.61 0.0092 1425 500/D
6 7/1.04 1.0 1.0 1.9 34.0 3.08 0.0078 1875 500/D
Certificates

IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)

Packing

 

IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)
International Fairs

 

IEC 60502 Type Cable0.6/1 Kv Cvv-Siec 60502 (2-15 core)Why Choose Us

1. Strict quality control system, excellent quality with reasonable price.

2. Strong and professional R&D team to meet your specific needs.

3. Rapid delivery and feedback. Faster lead time than our competitors.

4. OEM service available based on offical & legal authorization.

5. Free sample is available.

6. Appointed shipping company is acceptable.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier