Customization: | Available |
---|---|
Application: | Construction, Overhead, Underground, Industrial, Power Station |
Voltage: | Low and Medium Voltage Cable |
Still deciding? Get samples of US$ 0.5/Meter
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type | Description | Main application |
YJV/YJLV | Cu or Al conductor XLPE insulated PVC Sheath Power cable | For laying indoor and outdoor,unable to bear certain extermal mechanical force but the tractive force during laying.Laying Single core cable in magnetic duct is not permissble |
YJV22/YJLV22 | Cu or Al conductor XLPE insulated steel tape armored PVC sheathed power cable | For laying underground, bear external mechanical force, but unable to bear large pulling force |
YJV32/YJLV32 | Cu or Al conductor XLPE insulated thin steel wire armoured PVC sheathed power cable | For laying under ground, vertical well, or underwater, able to bear certain pulling force. |
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure,Convenient to use
d. Reduce costs
single core
Normal cross-sectional area of conductor mm2 |
Normal thickness of insulation mm |
Normal thickness of sheath mm |
Approx. overall diameter mm |
Approx.Weight KG/KM |
|||
YJV | YJY | YJLV | YJLY | ||||
1×1.5 | 0.7 | 1.4 | 6 | 47 | 37 | 38 | 28 |
1×2.5 | 0.7 | 1.4 | 6 | 59 | 49 | 44 | 33 |
1×4 | 0.7 | 1.4 | 7 | 77 | 65 | 52 | 40 |
1×6 | 0.7 | 1.4 | 7 | 99 | 86 | 62 | 49 |
1×10 | 0.7 | 1.4 | 8 | 147 | 131 | 84 | 68 |
1×16 | 0.7 | 1.4 | 9 | 209 | 191 | 109 | 91 |
1×25 | 0.9 | 1.4 | 11 | 304 | 283 | 149 | 127 |
1×35 | 0.9 | 1.4 | 12 | 400 | 377 | 184 | 160 |
1×50 | 1.0 | 1.4 | 13 | 524 | 498 | 232 | 205 |
1×70 | 1.1 | 1.4 | 15 | 732 | 701 | 310 | 279 |
1×95 | 1.1 | 1.5 | 17 | 991 | 953 | 404 | 367 |
1×120 | 1.2 | 1.5 | 18 | 1230 | 1189 | 490 | 449 |
1×150 | 1.4 | 1.6 | 20 | 1516 | 1467 | 603 | 554 |
1×185 | 1.6 | 1.7 | 23 | 1890 | 1832 | 748 | 690 |
1×240 | 1.7 | 1.8 | 26 | 2454 | 2384 | 954 | 884 |
1×300 | 1.8 | 1.8 | 28 | 3041 | 2965 | 1157 | 1081 |
Normal cross-sectional area of conductor mm2 |
Normal thickness of insulation mm |
Normal thickness of sheath mm |
Approx. overall diameter mm |
Approx.Weight KG/KM |
|||
YJV | YJY | YJLV | YJLY | ||||
2×1.5 | 0.7 | 1.8 | 10 | 105 | 84 | 86 | 62 |
2×2.5 | 0.7 | 1.8 | 10 | 134 | 111 | 102 | 79 |
2×4 | 0.7 | 1.8 | 11 | 173 | 148 | 123 | 99 |
2×6 | 0.7 | 1.8 | 12 | 226 | 198 | 150 | 122 |
2×10 | 0.7 | 1.8 | 15 | 342 | 307 | 214 | 178 |
2×16 | 0.7 | 1.8 | 17 | 488 | 448 | 285 | 244 |
2×25 | 0.9 | 1.8 | 21 | 711 | 663 | 393 | 345 |
2×35 | 0.9 | 1.8 | 23 | 927 | 873 | 486 | 433 |
2×50 | 1.0 | 1.8 | 21 | 1096 | 1045 | 499 | 448 |
2×70 | 1.1 | 1.8 | 23 | 1518 | 1460 | 657 | 598 |
Normal cross-sectional area of conductor mm2 |
Normal thickness of insulation mm |
Normal thickness of sheath mm | Approx. overall diameter mm | Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
3×1.5 | 0.7 | 1.8 | 10 | 127 | 105 | 99 | 77 |
3×2.5 | 0.7 | 1.8 | 11 | 167 | 143 | 120 | 96 |
3×4 | 0.7 | 1.8 | 12 | 221 | 194 | 145 | 118 |
3×6 | 0.7 | 1.8 | 13 | 293 | 263 | 179 | 149 |
3×10 | 0.7 | 1.8 | 16 | 445 | 408 | 253 | 215 |
3×16 | 0.7 | 1.8 | 18 | 647 | 604 | 342 | 299 |
3×25 | 0.9 | 1.8 | 22 | 959 | 908 | 482 | 431 |
3×35 | 0.9 | 1.8 | 24 | 1274 | 1217 | 613 | 556 |
3×50 | 1.0 | 1.8 | 24 | 1590 | 1530 | 695 | 634 |
3×70 | 1.1 | 1.8 | 28 | 2228 | 2154 | 935 | 861 |
3×95 | 1.1 | 2.0 | 31 | 3015 | 2927 | 1220 | 1132 |
3×120 | 1.2 | 2.1 | 34 | 3763 | 3661 | 1497 | 1396 |
3×150 | 1.4 | 2.3 | 38 | 4965 | 4533 | 1861 | 1738 |
3×185 | 1.6 | 2.4 | 42 | 5778 | 5636 | 2281 | 2138 |
3×240 | 1.7 | 2.6 | 47 | 7513 | 7339 | 2920 | 2746 |
3×300 | 1.8 | 2.8 | 52 | 9409 | 9202 | 3642 | 3535 |
Normal cross-sectional area of conductor mm2 |
Normal thickness of insulation mm |
Normal thickness of sheath mm |
Approx. overall diameter mm |
Approx.Weight KG/KM |
|||
YJV | YJY | YJLV | YJLY | ||||
4×1.5 | 0.7 | 1.8 | 11 | 154 | 130 | 117 | 93 |
4×2.5 | 0.7 | 1.8 | 12 | 204 | 177 | 142 | 109 |
4×4 | 0.7 | 1.8 | 13 | 274 | 245 | 175 | 146 |
4×6 | 0.7 | 1.8 | 14 | 363 | 330 | 214 | 181 |
4×10 | 0.7 | 1.8 | 17 | 559 | 518 | 307 | 266 |
4×16 | 0.7 | 1.8 | 20 | 815 | 767 | 416 | 368 |
4×25 | 0.9 | 1.8 | 25 | 1208 | 1151 | 585 | 528 |
4×35 | 0.9 | 1.8 | 27 | 1612 | 1549 | 747 | 684 |
4×50 | 1.0 | 1.9 | 28 | 2057 | 1983 | 886 | 812 |
Normal cross-sectional area of conductor mm2 |
Normal thickness of insulation mm |
Normal thickness of sheath mm |
Approx. overall diameter mm |
Approx.Weight KG/KM | |||
YJV | YJY | YJLV | YJLY | ||||
5×4 | 0.7 | 1.8 | 14 | 332 | 300 | 206 | 174 |
5×6 | 0.7 | 1.8 | 15 | 446 | 410 | 256 | 220 |
5×10 | 0.7 | 1.8 | 19 | 691 | 646 | 370 | 325 |
5×16 | 0.7 | 1.8 | 22 | 1007 | 954 | 499 | 446 |
5×25 | 0.9 | 1.8 | 25 | 1504 | 1441 | 710 | 835 |
5×35 | 0.9 | 1.8 | 28 | 2007 | 1937 | 905 | 947 |
5×50 | 1.0 | 2.0 | 33 | 2726 | 2634 | 1234 | 1142 |
5×70 | 1.1 | 2.1 | 37 | 3823 | 3712 | 1669 | 1558 |
5×95 | 1.1 | 2.3 | 43 | 5190 | 5050 | 2199 | 2059 |
5×120 | 1.2 | 2.4 | 48 | 6349 | 6187 | 2575 | 2413 |
5×150 | 1.4 | 2.6 | 53 | 7869 | 7673 | 3213 | 3017 |
5×185 | 1.6 | 2.8 | 59 | 9788 | 9552 | 3962 | 3726 |
5×240 | 1.7 | 3.0 | 67 | 12849 | 12564 | 5198 | 4913 |
5×300 | 1.8 | 3.2 | 74 | 15920 | 15584 | 6314 | 5978 |